  • If the coating roughness is not caused by the above reasons, it may be caused by impurities in the plating solution. Can take a small amount of electroplating solution, after filtration test, then take a small amount of electroplating solution, after zinc powder treatment test, check the problem is caused by solid particles or copper, lead and other foreign metal impurities. Test them one by one and it’s not hard to find the cause of the problem. Galvanized iron wire coating foaming, binding force is not good.

  • Zinc pot workers should be determined to do duty and responsibility. Do not leave the post without leave, always observe the change of hot plating wire galvanized layer, and according to the analysis results, master the asbestos block gap friction, how long it takes to press, replace the pressing face; Adjust the working face; Until all four sides of the asbestos block are used up, maintenance workers will continue to use the block after repair when necessary to reduce the consumption of asbestos block.

  • If the surface of galvanized wire hair black, galvanized layer is thin and uneven, this galvanized wire is partly because the inventory storage time is longer, it may also be because the production technical requirements of galvanized wire, do not meet the standard standards and lead to galvanized wire quality problems. According to the use of galvanized wire is different, galvanized wire has soft and hard, so the galvanized wire for binding requires the flexibility of galvanized wire is better, the flexibility of galvanized wire is good, which can facilitate the operation of workers.