  • The acceptance of cold-drawn low carbon steel wire shall be conducted according to the same production unit, the same raw material, the same diameter, and shall not exceed 30T for an inspection lot, and check the base material into the factory or out of the inspection statement. The inspection items for each inspection lot are appearance quality, diameter error, tensile test (including tensile strength and elongation) and repeated bending test.

    metal wire crate

    ...

    metal wire crate metal wire crate

    Read More
  • metal wire crate

    ...

    metal wire crate metal wire crate

    Read More
  • Take 20cm galvanized wire for acid fog experiment, check the zinc content of galvanized wire through the balance to see whether it meets the zinc layer standard required by customers, ensure that the metal wire achieves the role of rust and corrosion prevention, and meet the service life required by customers. Galvanized iron wires must be packed in good condition, bound neatly and orderly, and bound inward to prevent scratches during transportation. The inspection standard of galvanized iron wire also includes the tensile test, which is decided according to the material of the galvanized wire order ordered by the customer, and it needs to be tested by comparing the raw material list.

    metal wire crate

    ...

    metal wire crate metal wire crate

    Read More
  • Galvanized iron wire is widely used in construction, handicrafts, wire mesh, highway guardrail, product packaging and daily civilian and other fields.

    metal wire crate

    ...

    metal wire crate metal wire crate

    Read More
  • metal

    metal wire crate

    ...

    metal wire crate metal wire crate

    Read More
  • The management system of the rinsing water after the steel wire pickling should be regularly and regularly discharged after the rinsing water, and the rinsing water should be kept clean and low acid value as far as possible. The pH control is more appropriate. The concentration of plating aid should not be too high. Hot plating wire must be added ammonium chloride and zinc chloride according to the data of laboratory analysis, and the specific gravity of the composite solution is controlled in the range of 50~80g/L. The addition of ammonium chloride or zinc chloride raw materials without the results of laboratory analysis shall be subject to criticism and education, and economic treatment if necessary.