tie wire

tie wire

...

tie wire tie wire

Read More
  • Purpose of galvanized hexagonal net: building wall fixed, heat preservation, heat insulation; Power plant tied pipe, boiler warm; Anti-freezing, residential protection, landscaping protection; Raising chickens and ducks, isolating chicken and duck houses, to protect poultry; To protect and support seawalls, hillsides, roads and Bridges and other waterworks.

    tie wire

    ...

    tie wire tie wire

    Read More
  • In the process of composite electroplating galvanized wire, the plating solution must be stirred to obtain the composite coating in which the particles dispersed in the matrix metal. Stirring methods include mechanical stirring, air stirring, ultrasonic stirring, bath circulation, etc. The acid activation solution in the production process can remove the corrosion products and oxide film on the surface of the low carbon steel wire without excessive corrosion on the matrix.

    tie wire

    ...

    tie wire tie wire

    Read More
  • The protective duration of the galvanized layer of large roll galvanized wire is closely related to the thickness of the coating. Generally speaking, in relatively dry main gas and indoor use, and in harsh environmental conditions, the thickness of galvanized layer needs to be very high. Therefore, the environmental impact should be considered when choosing the thickness of galvanized layer. After passivation treatment of galvanized layer, a layer of bright old and beautiful color passivation film can be generated, which can significantly improve its protective performance.

    tie wire

    ...

    tie wire tie wire

    Read More
  • tie wire

    ...

    tie wire tie wire

    Read More
  • Galvanizing can be done by zincate galvanizing or chloride galvanizing. Appropriate additives shall be used to obtain a coating that meets the requirements of this standard. Luminescence treatment should be carried out after luminescence plating. The parts that need to be dehydrogenated for passivation should be passivated after dehydrogenation. Before passivation, 1%H2SO4 or 1% hydrochloric acid should be applied to activate 5~15s. Passivation shall be treated with colored chromate unless otherwise specified in the design drawings.

    tie wire

    ...

    tie wire tie wire

    Read More
  • tie wire

    ...

    tie wire tie wire

    Read More
  • tie wire

    ...

    tie wire tie wire

    Read More
  • 

    Popular articles

    Latest articles

    Links